SVT
Used for transferring and distribution of electrical power for switching installations and outdoor installation or for interior installation in rooms, in canals, tunnels, shafts or pits, at rated voltage Uo/U to 0,6/1 kV with frequency 50 Hz.
Upon request for resistance to atmosphere influence and sunlight radiation, is produced cable type SVT-s, with resistant sheath.
-
SVT-s
Used for transferring and distribution of electrical power for switching installations and outdoor installation or for interior installation in rooms, in canals, tunnels, shafts or pits, at rated voltage Uo/U to 0,6/1 kV with frequency 50 Hz.
Upon request for resistance to atmosphere influence and sunlight radiation, is produced cable type SVT-s, with resistant sheath.
-
SVBT
Used for transfer and distribution of electrical power for switching installation and in static installations, at rated voltage Uo/U to 0,6/1 kV with frequency 50 Hz.These cables are used for indoor installations, in the open air, in ditches, tunnels, canals and shafts.
-
SAVT
Used for transferring and distribution of electrical power for switching installations and outdoor installation or for interior installation in rooms, in canals, tunnels, shafts or pits, at rated voltage Uo/U to 0,6/1 kV with frequency 50 Hz.
-
SAVBT
Used for transferring and distribution of electrical power for switching installations and outdoor installation or for interior installation in rooms at rated voltage Uo/U to 0,6/1 kV with frequency 50 Hz.
These cables are used for indoor installations, in the open air, in ditches, tunnels, canals and shafts.
-
NYY
NYY is used in power plants industrial and switching installations, in secondary distribution networks and other.These cables are preferentially used in outdoor applications, for indoor instalations, in the open air, underground and in water where mechanical damage is not anticipated.
-
N2XY
The power cables with insulation of cross-linked polyethylene (XLPE) are designed for distribution and supply of consumers with nominal voltage 0.6/1 kV and frequency 50 Hz in industrial installations and urban networks.
They are suitable for fixed indoor assembly in cable ducts and conduits, over shelves and grilles, directly underground in ditch and outdoor under shelters providing the conditions determined for the type of cable.
-
NYBY
YBY is used in power plants, industrial and switching installations, for street lighting, domestic power supply connections, in secondary distribution networks and other.These cables are also used as control cables for transmission of measured values control and regulation pulses.These cables are preferentially used for underground application as well as for interior installation in room and cableducts and for outdoor and applications, for indoor installations, in the open air, underground and in water where greater mechanical protection an protection against accidental contact is required if damaged.
-
NAYY
NAYY is used in power plants industrial and switching installations, in secondary distribution networks and other.These cables are preferentially used in outdoor applications, for indoor instalations, in the open air, underground and in water where mechanical damage is not anticipated.
-
NAY2Y
Used in power plants industrial and switching installations, in secondary distribution networks and other.These cables are preferentially used in outdoor applications, for indoor instalations, in the open air, underground and in water where mechanical damage is not anticipated.
-
NYCY
NYCY is used in power plants, industrial and switching installations, for street lighting, domestic power supply connections, in secondary distribution networks and other.These cables are preferentially used for underground application as well as for interior installation in room and cableducts and for outdoor and applications, for indoor installations, in the open air, underground and in water where greater mechanical protection an protection against accidental contact is required if damaged.
-
NYCWY
NYCWY is used in power plants, industrial and switching installations, for street lighting, domestic power supply connections, in secondary distribution networks and other.These cables are preferentially used for underground application as well as for interior installation in room and cableducts and for outdoor and applications, for indoor installations, in the open air, underground and in water where greater mechanical protection an protection against accidental contact is required if damaged.