•   Каталог/Catalogue
  • Outdoor Composite Termination for 123 kV up to 170 kV The termination is designed for voltage classes up to 170 kV and to operate under severe environmental conditions. Polymeric insulated cables of various designs can be adopted with respect to shielding and metal sheath. Composite housings with different creepage lengths up to 50 mm/kV are available covering the most common and also extreme pollution levels according to IEC 60071-1 1996, IEC 60071-2 1996 and IEEE-1313.1-1996.

  • Dry Self-Supporting Outdoor Termination for 145 kV The dry self-supporting termination is designed for voltage class 145 kV and operation under severe environmental conditions. It is free from any insulating liquid or gel. Polymeric insulated cables of various designs can be adopted with respect to shielding and metal sheath. The polymeric housing with long creepage length covers extreme pollution levels according to IEC 60071-1 1996, IEC 60071-2 1996 and IEEE-1313.1- 1996. Its mechanical performance is similar to conventional oil-filled terminations with composite housing. The termination is easily separable and consists of a plug-in part and an epoxy resin insulator protected with a directly moulded silicone shed housing. Due to the short cable cutback dimensions of the plug-in the time required to install the termination is very short and can be further reduced in case of short cable links by pre-installing the plug-in on the shop floor. The plug-in is similar to the plug-in used with Tyco’s dry switchgear/transformer termination.

  • Switchgear and Transformer Termination for 72 kV up to 170 kV The switchgear termination for voltage classes up to 170 kV is designed to be installed in cable entry housings of gas-insulated switchgear (GIS). It complies with IEC 60859 and IEEE 1300 standards, which essentially specify the interfaces between the termination and the switchgear. Therefore the termination will fit into all GIS complying with these standards. The termination operates in SF6 but also in insulating liquids like transformer oil. A corona shield at the top of the transformer termination then provides the necessary shielding of the terminal.

  • Dry Compact Switchgear and Transformer Termination for 72 kV up to 170 kV The dry compact switchgear termination for voltage classes up to 170 kV is designed to be installed in cable entry housings of gas-insulated switchgear (GIS). It complies with IEC 60859 standard, which essentially specifies the interfaces between the termination and the switchgear. Therefore the termination will fit into all GIS complying with IEC 60859. An adapter is available to match the dimensions of wet (oil-filled) type terminations, which are also specified in IEC 60859. The termination operates in SF6 but also in insulating liquids like transformer oil. A corona shield at the top of the termination then provides the necessary shielding of the terminal. The termination is easily separable and consists of a plug-in part and an epoxy resin insulator. The insulator can be installed by the GIS or transformer manufacturer already at the factory saving installation time onsite and reducing the risk of contamination of the cable entry housing. In case of short cable links and due to the short length and light weight of the plug-in part it can be also preinstalled by the cable manufacturer further reducing the time required to install a substation.

  • Inline and Shield-Break Joint for 123 kV up to 170 kV The joint is a pre-fabricated three-piece design for voltage classes up to 170 kV. Polymeric insulated cables of various designs can be adopted with respect to shielding and metal sheath.