Terminations for polymeric and paper insulated cables 1 kV The terminations are designed for 3- and 4-core polymeric insulated cables with or without armour and 3- and 4-core paper insulated cables including cables with reduced neutral conductor. For example: NAYY, NAYBY, NAKBA, ВВГ, АВВГ, ПВГ, АПВГ, АпвВГб, ААБвУ, АСБУ, YAKY, XAKXS, KnFtA, AYKY, CYKY, CNKODY, ANKOY, ANKOPV, NAYY, NAYBY, NAKBA, PP 00-A, XP 00-A, N(A)YY, PP 41-A, N(A)YBY, N(A)YC(W)Y, IPO 13, N(A)KBA.
-
Terminations for belted, paper insulated cables (MI and MIND) with one common metal sheath 6 kV and 10 kV The indoor termination is designed for 6 kV and 10 kV three core belted, paper insulated (MI, MIND) cables. For example: SB, ASB, SAAB, AABY, ASBY, ААБУ, АСБУ, СБ2лГ, АСБ2лГ, СБнГ, АСБнГ, АивВГ, ПвПГ, Kny, KnFtly, AknFtA, AknFty, ANKOP, ANKOPV, CNKOY, CNKODY, IPO 13, IPO 14, NPO 13, NPO 14, N(A)KBA, N(A)KLEY.
-
Terminations for screened, paper insulated cables (MIND) with one metal sheath per phase 10 kV, 20 kV and 35 kV The indoor termination is designed for 10 kV, 20 kV and 35 kV screened three and single core paper insulated (MIND) cables with one metal sheath per phase. For example: ЦАОСБУ, HAKnFtA, HAKNY, HknFty, AMKTQYPVsp., AMKTOYPVsp., AOSB, NPZO 13, NPZOP 13, NPZO 23.
-
Indoor terminations for screened, paper insulated (MI) cables with one metal sheath per phase 10 kV and 20 kV The indoor termination is designed for 10 kV and 20 kV screened three and single core paper insulated (MI) cables with one metal sheath per phase. For example: AOUSZB, ЦАОСБУ, АОСБГУ, ОСБУ, ANKOY, CNKOY, ANKTOY-Vsp., ANKTOYP, AOUSZB, IPZO 13, IPZOP 13, IPZO 23, N(A)KLEY, N(A)HEKBA, N(A)EKBA.
-
Terminations for flexible, screened, rubber insulated cables 6 kV The termination is designed for 6 kV screened, flexible, rubber insulated cables with one or three earth cores. For example: NTSC, КГЭ, КГЭТ, Ogb, Ogc-G, CHCU, CBVU, EpN 64i65, EpN (BN) 64i74, EpN (BN) 76i78, EpN (BN) 78/53.
-
Terminations for unscreened, 3-core polymeric insulated cables 6 kV and 10 kV The indoor termination is designed for 6 kV and 10 kV unscreened three core polymeric insulated cables with armour or copper earth shield. For example: АПВГ, YAKYFtly, YKYFoY, YAKYFpy, AYKCY, CYKCY, NAYFGY, PP 41-(A), PP 44-(A), PP45-(A), N(A)YFGY.
-
Terminations for screened, 3-core polymeric insulated cables 10 kV, 15 kV, 20 kV and 35 kV The indoor termination is designed for 10 kV, 15 kV, 20 kV and 35 kV screened, three core polymeric insulated cables with or without armour or copper tape shield. For example: N(A)YSEY, NA2XSY, N2XSEY, NA2XS2Y, АпвБ, АпвБШв, AXEKVCY, AXEKVCEY, N(A)2XSY, XHP 81, EpHP 81, PHP 48,PHP 84, XHP 48.
-
Terminations for screened, 1-core polymeric insulated cables 10 kV, 15 kV, 20 kV and 35 kV The indoor termination is designed for 10 kV, 15 kV, 20 kV and 35 kV screened single core polymeric insulated cables. For example: АпвВ, ПвП, YHAKXS, XUHAKXS, YHKXS, AXEKVCY, AXEKVCEY, CXEKVCEY, N(A)2XSY, SZAQkrKM, SZAXRkKM, XHE 49, XHP 48, EHP 48, N(A)2XS(F)2Y, AHXAMK-W, NF C 33-223.
-
Elastomeric terminations for screened, 1-core polymeric insulated cables with wire screen 10 kV, 15 kV, 20 kV and 35 kV The termination is designed for 10 kV, 15 kV, 20 kV and 35 kV screened single core polymeric insulated cables with wire screen. For example: NA2XS2Y, YHAKXS, XUHAKXS, AXEKVCE, AXEKVCEY, CXEKVCEY, N(A)2XSY, XHE 49, XHP 48, EHP 48, N(A)2XS(F)2Y.
-
Terminations for screened, polymeric insulated filter cables up to 150 kV D.C. The termination is designed for screened single core polymeric insulated cables with wire shield or metal sheath, cross section from 35 mm2 to 240 mm2 and diameter over insulation between 26 mm and 52 mm. Cables designed for D.C. voltages 111 kV or 150 kV usually meet the dimensional requirements.
-
Terminations for polymeric insulated cables for electrified Railway systems 25 kV A.C. The termination is designed for screened single core polymeric insulated cables with wire shield, cross section from 150 mm2 to 240 mm2 and diameter over insulation between 30 mm and 45 mm. Cables designed for A.C. voltages (3 phase systems) Uo/Um of 30/52 kV or 41/72,5 kV usually meet the dimensional requirements. The termination is tested to IEEE-48-1990 which exceeds the requirements of IEC-60840-1999-2 for cables and accessories with max. system voltages up to Um 52 kV. This covers applications in railway networks with nominal voltage of 25 kV (phase to ground) as defined in EN 50163 with Umax1 of 27,5 kV (no time limit) and Umax2 of 29 kV (max. 5 min).